SY-1200L Types Of Syringe Medfusion Pump SY-1200L Types Of  Syringe Medfusion Pump

Service time: 24 hours
Min order :5PCS
CE certificate
Sales mode:Wholesale
Best selling syringe pump with competitive prices

Quantity:
Share this:

SPECIFICATION

SY-1200L Types Of  Syringe Medfusion Pump 

1-4.jpg

1-1.jpg

1-2.jpg

FEATURES

Function :

·        KVO     (keep-vein-open)           

·        Safety lock for PURGE/BOLUS

·        Apply to any high elastic infusion sets        

·        Preset occlusion detection pressure level (three levels)                         

·        Preset Volume To Be Infused                                  

·        Audible and visual alarm (volume adjustable)             

·        RS232 interface                     

·        History data memory

·        Standby function

·        Safety lock for flow rate adjust

·        Bubble Detector

·        Bolus release

·        Inquiry of total infused volume

·        Power indicator

·        Vehicle Power

·        Double CPU


 

 

Technical parameters:

 

Parameter   SY-1200 Infusion pump


Conventional   model

15 d/ml   infusion   set                 0.0ml/h~1200ml/h 

20 d/ml   infusion   set                 0.0ml/h~1200ml/h

60 d/ml infusion   set                 0.0ml/h~300ml/h

Note:minimum   resolution of setting flow rate is 0.1mL/h when rate is above 1000mL/h,   the Resolution is 1mL/h.

 

Drip   Mode

15 d/ml   infusion   set                 0 d/min~300 d/min

20 d/ml   infusion set                 0 d/min~400 d/min

60 d/ml   infusion   set                 0 d/min~300 d/min   

Note:The   minimum resolution dripping speed Settings 1d/min.

Accuracy

≤±2%(Note:Under   the condition of the benchmark test, using high elastic silicone iv path   accuracy after calibration and commissioning.)

Bubble   Detector

Ultrasonic   detection method:Bubble   above 25ul is detected

Total   Infusion Volume

0.0ml-9999ml(0.1ml/h   increment,1ml/h increment if over 1000ml/h)

Volume   Limit

0.0ml-9999ml(0.1ml/h   increment,1ml/h increment if over 1000ml/h)

Occlusion

(H):800±200mmHg (106.7±26.7kPa)

(C):500±100mmHg (66.7±13.3kPa)

(L):300±100mmHg (40.7±13.3kPa)

History   Record

These   serial products can maximally store 4500 pieces of history records. The   record includes the following information: Date, flow rate, alarm data, total   volume delivered, occlusion pressure and syringe brand and serial number.

Alarm

Near   empty alarm,Empty   alarm,Door   open alarm, Bubble   alarm,limited   value reached alarm,AC power   failure,Low   battery alarm,Battery   empty alarm,Remind   alarm,Flow   regulator or inlet valve closed alarm (optional)

Power

Supply   Voltage:AC100V~240V(±10%),Power   Frequency: 50Hz-60Hz

Built-in   Battery:DC15V   Ni-MH battery(It can   be replaced by lithium ion battery pack necessary.)

Working   time of battery:In case   the battery is fully charged, the continuous working time can

be up to   6 hours at the speed of 25ml/h.

Maximum   power:30VA;Note:Before   the first use of this product, the battery must be charged while being   shut down for more than 12 hours.

Working   Environment

Temperature:+5℃-+40℃

Relative   humidity:20%-90%

Environmental   pressure:860hPa-1060hPa

Transport   And Storage Environment

Temperature:-20℃~+55℃;

Atmosphere   Pressure:500hPa~1060hPa.

products   should be stored in the relative humidity in the range of 10% ~ 93%,no   corrosion gas indoor and ventilated.

Electric   Safety Classification

Class I,   CF type,Built-in   battery,Continuous   operation equipment

Water   Proof Level

IPX4

Net   Weight

1.8kg(include   fastener)

Dimension

175mm(W)×125mm(H)×200mm(D)

Function


KVO       (keep-vein-open)           

Safety   lock for PURGE/BOLUS

Apply to   any high elastic infusion   sets        

Preset   occlusion detection pressure level (three levels)                             

Preset   Volume To Be   Infused                                    

Audible   and visual alarm (volume   adjustable)             

RS232   interface                       

History   data memory

Standby   function

Safety   lock for flow rate adjust

Bubble   Detector

Bolus   release

Inquiry   of total infused volume

Power   indicator

Vehicle   Power

Double   CPU

Advanced   Function


Adjust   occlusion detection   pressure                 

Adjust   KVO rate

A single   exhaust maximum limit set

Calculation   mode,Gradient   mode

Infusion   parameters calibration

Intelligent   pressure test

Preset   maximum value of flow rate

Preset   system time

 


PRODUCT DETAILS


1CE CERTIFICATE for Annecy machinery.jpg1hospital bed.jpg




PACKAGING&SHIPPING

Packaging:

Generally, we pack our goods in noutral cardboard box or wooden box. If you have legally registered patent, we can pack the goods in your branded boxes

atter geting your authorization iatpers.

Shipping:

Generally, it will lake 7 1o 20 days affer receiving your advance payment

Te specifc delivery lime depano on te lams ind the quantiy of your order.

Sample Availability & Pollcy

We can supply the sample if we have reacy parts in stock, but the cuslomers have to pay the sample cbst and the courier cost.

Annecy详情页3_22_副本_副本


Product Inquiry

ZHANGJIAGANG ANNECY MACHINERY CO.,LTD.

ZHANGJIAGANG ANNECY MACHINERY CO.,LTD.

×

Contact Us